Hazardous Area Classification Made Easy

Standards-based zone classification and safety calculation tools for engineers and safety professionals.

Substance data sources: ISO/IEC 80079-20-1:2017 · PubChem · NIST WebBook

Available modules

✓ Available
IEC 60079-10-1:2020

Gas & Vapour Zone Classification

Full implementation of the IEC 60079-10-1:2020 procedure: release rate (Annex B), ventilation assessment (Annex C + EN 16798-7), dilution chart (Figure C.1), zone type (Table D.1), and zone extent (Figure D.1).

✓ Available
IEC 60079-10-1:2020 · Annex F

Qualitative Hazardous Area Classification

Schematic (flowchart) zone classification per Annex F. No release-rate calculation required — enter grade, dilution and ventilation availability to determine zone type from Table D.1. Generates a flowchart PNG suitable for copy-paste into documentation.

✓ Available
IEC/TS 60079-32-1:2013+A1:2017

Electrostatic Hazards Evaluation

Systematic electrostatic evaluation per Annex F, Figure F.1. Walk the conductive/dissipative or insulating path to identify the expected discharge type — corona, spark, propagating brush, cone or brush — with every clause and table explained inline, and a downloadable editable block-diagram report (PPTX).

✓ Available
CEN/TR 15281:2022

Inerting — Explosion Prevention

Swing inerting (pressure and vacuum) and flow-through purging calculations per CEN/TR 15281:2022 Annexes A and B. Determines the number of inerting cycles or purging time/flow required to reach a target O₂ concentration.

✓ Available
IEC 62485-2:2010

Battery Rooms — Stationary Batteries

Ventilation flow rate, natural ventilation opening area and safety distance for rooms containing stationary secondary batteries (lead-acid vented, VRLA, NiCd). Includes adequacy check against existing extraction capacity and Section 9.2 attention items.

✓ Available
IEC 62485-3:2014

Traction Battery Charging Areas

Minimum ventilation flow rate, natural ventilation opening area, free volume adequacy check and fixed safety distance for forklift and traction battery charging areas (lead-acid, VRLA, NiCd). Covers regulated and unregulated chargers; simultaneous charging of multiple vehicles.

✓ Available
EN 16985:2018

Spray Booth Classification

Hazardous area classification for spray application equipment and spray booths per EN 16985:2018 Annex C. Covers liquid (multi-solvent), powder, water-based product booths and post-spray purge time calculation.

✓ Available
EN 1539:2015

Dryers & Ovens — Flammable Substances

Safety ventilation calculations for Type A dryers and ovens per EN 1539:2015 Annex A. Covers chamber dryers (Method A) and continuous flow dryers. Assessment, design Q and design load modes; Table 2 safety requirements per operating range.

✓ Available
IGEM/SR/25 Ed.2 · 2013

Natural Gas — Hazardous Area Classification

Outdoor installation classification per IGEM/SR/25 Edition 2. Table lookup (Table 1 freely ventilated, Table 2 congested / confined) by operating pressure and site conditions. Covers flanges, screwed fittings, valve glands and regulators. Zone 0/1/2 or NE per grade of release.

Request access or ask a question

HACacare is an invitation-only tool. To request an account or ask about the project, reach out at .